PORTABLE GAS LEAK DETECTOR Type : BG-30 Trotec Spesification: Accuracy : 50 ppm Standard Calibration : Methane Alarm Treshold : Alarm Level max 10% Reaction Time : < 2 second ( up to 40% LEL) ....
Specification : Measuring Element : - Digital Sensors CMOS - Hygrometry : 5 - 95% RH - Temperature : -20 to 70 ° C Accuracy :  ± 0.4% of reading  ± 0.3 ° C  ± 1.8% HR Display : 1 line, LCD....
Specification : Measuring Element : Digital Sensor ( CMOS) Display : 4 lines, LCD technology. Sizes 50 x 34.9 mm. 2 lines of 5 digits with 7 segments ( value) 2 lines of 5 digits with 16....
Coconut Charcoal Tube Standard, 50/ 100 mg Size : 6 x 70 mm Qty : 50 pcs / box
Handheld Flue Gas Analyzer A550 Woehler Spesification: Parameter gas : up to 5 sensor gas Type Gas : O2, CO, NO/ NOx. SO2, NO2 Insertion probe for a variety of measurement tasks Spillage Test....
Specification : Spectral response..................8 - 14 Â ¼ m Optical.....................................D.S : 20: 1 ( 13 mm at 260 mm) Temperature range.................From -50 to + 800Â ° ....
Specification : Spectral response.......................8 -14 Â ¼ m Optical..........................................D.S : 30: 1 ( 50 mm at 1500 mm) Response time................................
Specification : Spectral response : 8 - 14 Â µ m Optical : D.S : 50: 1 ( 50.8 mm at 2540 mm) Temperature range : From -50 to + 1850Â ° C Accuracy* : From -50 to + 20Â ° C : Â ± 3Â ° C From + 20 to ....
LABORATORY REFRIGERATED CENTRIFUGE Specification : - : 230V 50/ 60Hz; 115V 50/ 60Hz : 200W : 500ml : 100 à · 18000 rpm : 24088 x g : 0 à · 99min 59s, or  °  ° , 1s interval : 365 x 495 x....
Wohler KM-410 IAQ Meter. to measure and verifying HVAC system performance and air ventilation control such CO2 content, Air Temp, Humidity, CO content, dew point and wet bulb temp. Parameter : ....
Specification : Display.........................................Graphic display 320x240 pixels Dim. 70 x 52 mm, color display Display of 6 measurements ( including 4 simultaneously) Housing....
Specification : Solar irrigation measuring range..........from 1 W/ m2 to 1300 W/ m2 Energetic exposure measuring range...from 1 Wh/ m2 to 500 kWh/ m2 Frequency of the measure......................
TSP HIGH VOLUME AIR SAMPLER Type : HVP-5300AFC Product : HI-Q ( USA) TSP Hi-Vol - Automatic/ PID Mass or Volumetric Flow Control - Networking & Comunication capabilities - Continuous Data....
Specification: Standards : IEC 61672-1 Class 2 / IEC 60651 Class 2 / IEC 60804 Class 2 Measured parameters : LA and LAeq Other displayed parameters: LAFmax, LAFmin, LASmax , LASmin Frequency....
WBGT T-103F, HEAT STRESS METER Function : Determining wet bulb and globe temperature. Also to reduce the heat stress injures. Spesification : APPLICATION: WBGT measurement under thermally....